Load Control Software
The EES-100 load control software for primary and secondary batteries allows
calibration to any current range. It lets the
user smooth the current and voltage readings,
store data collection, save profiles settings,
and adjust communication rates. Three different
full scale voltage settings are available for
unit under test (UUT) with a compensation adjust
for each respective range.
This software runs the electronic load(s) in constant
current, constant voltage, constant resistance,
and constant power. An extended range of extra
control commands is included for timing tests,
series resistance, amp hours and up/down timing.
It graphs data, stores data, and outputs data
in Ascii CSV and/or Excel formats. Minimum and
maximum auto stop settings for current and voltage
are also included. Many other features needed
for primary and secondary cell testing are also
included.
Visit www.Exec-Eng.com to download demo software
or contact Executive Engineering, 3143 N.W. 41st
Street, Lauderdale Lakes, FL 33309, phone: (954)
485-0177.
|